Porozit N2
Preload 1 Preload 2 Preload 3 Preload 4 Preload 5 Preload 6 Preload 7 Preload 8 Preload 9

Porozit N2

Reliable porosity measurement system trusted by professionals. Accurate, consistent, and easy to operate in real inspection conditions.

€845,00


  • High-precision gravitational airflow measurement
  • Updated body with improved sealing performance
  • Porozit N2 has double neodymium magnets to eliminate false air
  • Narrow head design — fits all XC paraglider cells
  • More precise trigger mechanism for repeatable measurements
  • 4-digit LED display (4×7 segment)
  • Results in seconds with consistent accuracy
  • 24h continuous operation with built-in rechargeable battery

Estimated delivery icon Estimated delivery:  Delivery icon Shipping calculated at checkout Package Include icon Included:   Porozit N2 Body, N2 Control Unit, RCA Cable, USB-C Charging Cable, Power Adapter, Carrying Bag, User Manual, Stickers
learn more Icon
  • General Information
  • Tech Specs
  • How to Use
Reliable Measurement. Proven in the Field.

Reliable Measurement. Proven in the Field.

The Porozit N2 Complete Instrument is a professional porosity measurement system designed for paraglider inspections, maintenance, and service applications. Built on a proven measurement principle, it delivers accurate and repeatable results in both workshop and field conditions.

Used by paragliding service centers, inspection professionals, and manufacturers worldwide, the N2 has become a trusted tool for evaluating fabric condition and supporting safety-critical decisions.

Trusted by Professionals Worldwide

The Porozit N2 system is used across 67 countries, making it one of the most widely adopted porosity measurement solutions in the paragliding industry.

From independent inspectors to large-scale manufacturers, professionals rely on the N2 for its consistency, durability, and ease of use in real-world environments.

Precision engineering where it matters

Precision engineering where it matters

At the core of the system is the redesigned Porozit body, featuring:

  • Double neodymium magnets for strong sealing and elimination of false air
  • High rubber wall design for better contact on worn or high-porosity fabrics
  • Narrow head geometry for accessing tight XC paraglider cells
  • Refined trigger mechanism for consistent and repeatable measurements

These improvements are based on real feedback from field use, ensuring reliable performance in demanding conditions.

Designed for Inspection Workflows

Designed for Inspection Workflows

The N2 Complete is built specifically for inspection and service workflows, where reliability and speed are essential.

  • Fast measurement process
  • Clear and easy-to-read results
  • Minimal setup and intuitive operation

This allows professionals to perform full wing inspections efficiently, without unnecessary complexity.

The N2 control unit is designed for straightforward operation, allowing users to focus entirely on measurement.

With a clear LED display and minimal controls, it provides a dependable and distraction-free workflow—ideal for professionals who need accurate results without advanced interface complexity.

Evaluation of Measurements Excellent

Evaluation of Measurements Excellent

  • Good: < 375 l/m²/min / > 20 sec
  • Acceptable: 375-536 l/m²/min / 14-20 sec
  • Fail: > 536 l/m²/min / < 14 sec

In the Settings you can change the unit of l/m²/min (at 200 mm water pressure).

Measurement Specifications

Average measurement vacuum
-
10 mbar
Airflow surface area
-
38.5 cm²
Measured air volume
-
250 cm³
Measurement accuracy
-
±3%
Relative humidity (max)
-
60%
Operating temperature range
-
+15 °C to +25 °C

Intrument (Porozit N2 Body)

Measurement principle
-
Gravitational airflow measurement
Dimensions
-
20cm × 20cm × 32cm
Weight
-
4.1 kg
Magnetic system
-
Dual neodymium magnets for high sealing force
Sealing design
-
High rubber wall for improved contact on high-porosity materials
Head design
-
Narrow geometry for XC paraglider cells
Trigger mechanism
-
Precision mechanical trigger for consistent activation
Airflow system
-
Closed measurement chamber minimizing false air

Power & Battery

Battery type
-
Li-Po
Battery capacity
-
1800 mAh
Operating time
-
~24 hours
Charging
-
USB-C
Charging input
-
5V / 1.2A
Included adapter
-
5V / 2A
Full charging time
-
~3 hours
Charging note
-
USB-C cable and power adapter included

Display

Display type
-
High-brightness LED (4×7 segment)

Device

Dimensions
-
120 × 75 × 28 mm
Weight
-
150 g
Housing material
-
ABS

Functionality

Measurement units
-
sec

Connectivity

Connection
-
RCA
Compatibility
-
Compatible with all Porozit bodies
Operating temperature
-
-10 °C to +50 °C
Water resistance
-
No

How to Use – Porozit N2

1. Connect

1. Connect

Connect the control unit to the Porozit body and plug the jack cable into the control unit and the RCA cable into the body.

2. Remove the lid

2. Remove the lid

Remove the top lid from the measurement head

3. Place the fabric

3. Place the fabric

Place the fabric between the body and the lid, then close it securely

4. Start the Measurement

4. Start the Measurement

Turn on the device and wait until the display is ready and shows “0”

5. Run the Test

5. Run the Test

Release the trigger to let the internal cylinder fall freely and wait for the beep indicating the end of the measurement.

How to use

Inputs

Inputs

  1. RCA input for connection to the Porozit Body
  2. USB-C charging port (max. 2A)
Buttons & Display

Buttons & Display

  1. Battery indicator (red = charging, green = fully charged)
  2. Power button (turns the device on/off)
  3. 4-digit display (seconds)
  4. Reset button (resets the measurement)

Beep Interval Adjustment

Beep Interval Menu

Beep Interval Menu

  1. Press the Power button
  2. Before “0” appears on the display, press and hold the Reset button
Set the Interval

Set the Interval

  1. The display shows “t 90” (90 seconds). This is the default beep interval
  2. Press the Reset button to adjust the interval from 0 to 300 seconds in 30-second steps (“0” means the sound is muted)
Save the Settings

Save the Settings

  1. Press and hold the Reset button to save the selected value
  2. Turn the device off and on again (using the Power button)

Battery Display

Battery level

Battery level

  1. When the device is turned on, the display shows the battery level using vertical bars. 1 bar = 12.5% | 8 bars = 100% | 2 bars = 25%


Porozit Devices

Porozit N2 Device
Porozit N2+ Device